Leave Your Message

China H14 Mini-Pleated HEPA Filter Fan Filter Unit - High-Efficiency Purification Suppliers & Factory

,

Introducing our high-quality filtration systems manufactured from durable materials, including steel paint, galvanized plates, or stainless steel. As a leading supplier in China, our factory guarantees exceptional performance and reliability.

,

Our filtration systems are powered by versatile electricity options, featuring AC 110V or 220V (50Hz or 60Hz) and 220V or 380V (50Hz or 60Hz), ensuring compatibility with a variety of operating environments.

,

Experience advanced speed control functionality with options for three-speed, five-speed, or stepless speed regulation (for three-phase power), allowing for precise adjustments tailored to your needs.

,

Our products boast impressive filtration efficiency, achieving up to 99.99% at 0.3μm, 99.995% at 0.3μm, and 99.9995% at 0.12μm, meeting rigorous standards including EN1822, Class H13/H14/U15.

,

Designed to operate under optimal conditions, our filtration systems maintain high performance with a temperature threshold of ≤70℃ and humidity levels up to 100% RH.

,

    Application area

    • Electronics Industry: Semiconductor chip fabrication rooms, LCD panel production lines, precision PCB assembly rooms.
    • Pharmaceutical and Bioengineering: Sterile preparation areas, vaccine production lines, Bio safety Laboratories (BSL-2/3), sterile filling lines.
    • Healthcare: Hospital operating rooms, sterile wards, ICU, bone marrow transplant wards.
    • Food and Beverage: Aseptic packaging areas, pro biotic production zones, dairy product fermentation rooms.
    • Scientific Research: Animal laboratories, microbiology labs, precision instrument rooms.

    FFU Structure

    Casing

    Material: Typically made of stainless steel or galvanized aluminum steel sheet, with anti-rust and anti-corrosion surface treatment. These materials ensure structural strength, resistance to rust, and minimal particle generation.

    Functions:

    • Support Frame: Provides structural support for the entire FFU, enabling it to be securely embedded into the ceiling grid (T-Bar) of the clean room.
    • Air Guidance: The internal design of the casing (e.g., guide vanes) helps optimize airflow, reduce turbulence, and ensure more uniform air passage through the filter.
    Power Section – Fan

    This is the "heart" of the FFU, typically a direct-drive backward-curved centrifugal fan (EC or AC fan).

    Motor Types:

    • AC Motor: Uses an alternating current motor, with speed controlled by voltage regulation. Simple structure and lower cost, but relatively lower energy efficiency and less precise control.
    • DC Motor: Uses a brush less DC motor. This is the most mainstream type today. It offers high energy efficiency, long lifespan, low noise, and minimal vibration.
    • EC Motor: Electronically Commutated motor, an advanced form of DC motor. It combines the advantages of both AC and DC motors, operates directly on AC power while converting it internally to DC to drive the motor, providing extremely high energy efficiency and precise control performance.

    Features: The fan is directly connected to the motor, eliminating the need for belt drives. This avoids contamination from belt wear, results in a more compact structure, and simplifies maintenance.

    Filtration Section – HEPA/ULPA Filter

    This is the "lungs" of the FFU, responsible for filtering airborne particles.

    Types: The vast majority of FFU use HEPA filters, while ULPA filters are used for more stringent requirements.

    Installation Methods:

    • Gel Seal: The filter frame has a channel filled with sealant gel. It mates with a knife-edge on the FFU casing, creating an airtight seal using the gel (e.g., jelly-like sealant). This is the most efficient and reliable sealing method, commonly used in high-grade clean rooms.
    • Mechanical Clamping + Gasket Seal: The filter is pressed against the casing via a spring or bolt mechanism, with a rubber or polyurethane gasket in between. This method is relatively easier to install and has a lower cost.
    Other Key Components

    Control Unit:

    • Individual Controller: Each FFU is equipped with a separate speed controller (knob or digital display) for individual airflow adjustment.
    • Group Control System: A central management system that monitors, adjusts speeds, and manages alarms for hundreds or thousands of FFU collectively via a network or bus (e.g., RS485, Ethernet), enabling intelligent control.

    Pre-filter: A primary or medium-efficiency filter located on the fan's intake side. Its purpose is to protect the fan and extend the service life of the more expensive downstream HEPA/ULPA filter.

    Airflow Equalizing Plate: A perforated plate located below the HEPA/ULPA filter. It helps to make the clean airflow exiting the filter more uniform and stable, preventing turbulent flow.

    The efficiency of HEPA Filter

    • HEPA: Filtering efficiency ≥ 99.97% for particles ≥ 0.3μm.
    • ULPA: A higher-grade filter, efficiency ≥ 99.999% (for 0.1-0.2μm particles). Used in ultra-high standard fields like semiconductors and bio safety laboratories.
    HEPA Filter (1)
    HEPA Filter (2)
    HEPA Filter (3)
    HEPA Filter (4)

    Service Life of Filters

    As dust accumulates on the filter media, the resistance increases. When the resistance reaches an unreasonable level, the filter must be discarded. Sometimes, excessive resistance can cause previously captured dust to become dislodged and re-enter the airflow; when this risk arises, the filter should also be replaced. The resistance of a filter increases with higher airflow rates. By increasing the surface area of the filter media, the relative velocity of air passing through the filter can be reduced, thereby decreasing the resistance.

    Standard form

    Standard form

    Technical Parameters

    Technical Parameters 3

    EC FFU

    EC FFU

    EC FFU Parameters

    EC FFU Parameters

    Remarks: (1) Initial resistance tolerance of± 10% (2) Support customer size

    Frequently Asked Questions (FAQ)

    What are the primary applications of a Fan Filter Unit (FFU)?

    FFUs are widely utilized in environments requiring strict contamination control, such as the electronics industry (semiconductor and LCD manufacturing), pharmaceutical and bioengineering sectors, healthcare facilities (operating rooms and ICUs), food and beverage processing, and scientific research laboratories.

    What is the difference between AC, DC, and EC motors in FFU units?

    AC motors are cost-effective but less energy-efficient with limited speed control. DC motors offer higher efficiency, low noise, and a longer lifespan. EC (Electronically Commutated) motors combine AC and DC benefits, running on AC power but converting it to DC internally, providing maximum energy efficiency and precise digital control.

    How do HEPA and ULPA filters differ in performance?

    HEPA filters provide a filtration efficiency of ≥ 99.97% for particles ≥ 0.3μm, which is suitable for most standard clean rooms. ULPA filters offer a higher efficiency of ≥ 99.999% for smaller particles (0.1-0.2μm), commonly used in ultra-clean semiconductor and biosafety laboratory applications.

    What are the common installation sealing methods for FFU filters?

    The two primary methods are Gel Seal and Mechanical Clamping. Gel Seal uses a sealant gel channel to create a highly reliable, airtight seal ideal for high-grade clean rooms. Mechanical Clamping uses springs or bolts to press the filter against a rubber/polyurethane gasket, offering a simpler and lower-cost installation.

    When should an FFU filter be replaced?

    Filters must be replaced when dust accumulation causes the airflow resistance to reach an unreasonable limit, or when there is a risk of captured dust dislodging and re-entering the clean room space due to high resistance.