【Material】Crafted from high-quality steel paint, galvanized plates, or stainless steel, our products ensure durability and longevity.

【Power Source】Available in various configurations, including AC 110V or 220V at 50Hz or 60Hz, as well as 220V or 380V options for both 50Hz and 60Hz, catering to diverse power requirements.

【Speed Control Function】Our equipment features versatile speed control options, including three-speed and five-speed settings, along with stepless speed regulation for three-phase power systems, providing precise control over operation.

【Filtration Efficiency】Engineered for superior performance, our filters achieve an impressive filtration efficiency of 99.99%@0.3μm, 99.995%@0.3μm, and 99.9995%@0.12μm, making them ideal for demanding applications.

【Standard】Meets rigorous standards of EN1822, classified under H13/H14/U15, ensuring compliance with industry regulations.

【Operating Conditions】Designed to perform under extreme conditions, our products operate effectively at temperatures up to 70℃ and humidity levels reaching 100% RH.

As a leading manufacturer and supplier in China, our factory is committed to providing top-tier products that meet the highest quality standards.

    Application Area

    Electronics Industry

    Semiconductor chip fabrication rooms, LCD panel production lines, precision PCB assembly rooms.

    Pharmaceutical & Bioengineering

    Sterile preparation areas, vaccine production lines, Bio safety Laboratories (BSL-2/3), sterile filling lines.

    Healthcare

    Hospital operating rooms, sterile wards, ICU, bone marrow transplant wards.

    Food and Beverage

    Aseptic packaging areas, pro biotic production zones, dairy product fermentation rooms.

    Scientific Research

    Animal laboratories, microbiology labs, precision instrument rooms.

    FFU Structure

    Casing

    Material: Typically made of stainless steel or galvanized aluminum steel sheet, with anti-rust and anti-corrosion surface treatment. These materials ensure structural strength, resistance to rust, and minimal particle generation.

    Functions:

    • Support Frame: Provides structural support for the entire FFU, enabling it to be securely embedded into the ceiling grid (T-Bar) of the clean room.
    • Air Guidance: The internal design of the casing (e.g., guide vanes) helps optimize airflow, reduce turbulence, and ensure more uniform air passage through the filter.

    Power Section – Fan

    This is the "heart" of the FFU, typically a direct-drive backward-curved centrifugal fan (EC or AC fan).

    Motor Types:

    • AC Motor: Uses an alternating current motor, with speed controlled by voltage regulation. Simple structure and lower cost, but relatively lower energy efficiency and less precise control.
    • DC Motor: Uses a brush less DC motor. This is the most mainstream type today. It offers high energy efficiency, long lifespan, low noise, and minimal vibration.
    • EC Motor: Electronically Commutated motor, an advanced form of DC motor. It combines the advantages of both AC and DC motors, operates directly on AC power while converting it internally to DC to drive the motor, providing extremely high energy efficiency and precise control performance.

    Features: The fan is directly connected to the motor, eliminating the need for belt drives. This avoids contamination from belt wear, results in a more compact structure, and simplifies maintenance.

    Filtration Section – HEPA/ULPA Filter

    This is the "lungs" of the FFU, responsible for filtering airborne particles.

    Types: The vast majority of FFU use HEPA filters, while ULPA filters are used for more stringent requirements.

    Installation Methods:

    • Gel Seal: The filter frame has a channel filled with sealant gel. It mates with a knife-edge on the FFU casing, creating an airtight seal using the gel (e.g., jelly-like sealant). This is the most efficient and reliable sealing method, commonly used in high-grade clean rooms.
    • Mechanical Clamping + Gasket Seal: The filter is pressed against the casing via a spring or bolt mechanism, with a rubber or polyurethane gasket in between. This method is relatively easier to install and has a lower cost.

    Other Key Components

    Control Unit:

    • Individual Controller: Each FFU is equipped with a separate speed controller (knob or digital display) for individual airflow adjustment.
    • Group Control System: A central management system that monitors, adjusts speeds, and manages alarms for hundreds or thousands of FFU collectively via a network or bus (e.g., RS485, Ethernet), enabling intelligent control.

    Pre-filter: A primary or medium-efficiency filter located on the fan's intake side. Its purpose is to protect the fan and extend the service life of the more expensive downstream HEPA/ULPA filter.

    Airflow Equalizing Plate: A perforated plate located below the HEPA/ULPA filter. It helps to make the clean airflow exiting the filter more uniform and stable, preventing turbulent flow.

    The Efficiency of HEPA Filter

    Standard High Efficiency

    HEPA: Filtering efficiency ≥ 99.97% for particles ≥ 0.3μm.

    Ultra-High Efficiency

    ULPA: A higher-grade filter, efficiency ≥ 99.999% (for 0.1-0.2μm particles). Used in ultra-high standard fields like semiconductors and bio safety laboratories.

    Service Life of Filters

    As dust accumulates on the filter media, the resistance increases. When the resistance reaches an unreasonable level, the filter must be discarded. Sometimes, excessive resistance can cause previously captured dust to become dislodged and re-enter the airflow; when this risk arises, the filter should also be replaced. The resistance of a filter increases with higher airflow rates. By increasing the surface area of the filter media, the relative velocity of air passing through the filter can be reduced, thereby decreasing the resistance.

    Standard Form

    Standard form

    Technical Parameters

    Technical Parameters 3

    EC FFU

    EC FFU

    EC FFU Parameters

    EC FFU Parameters
    Remarks: (1) Initial resistance tolerance of ± 10%  |  (2) Support customer size

    Frequently Asked Questions (FAQ)

    Q: What is a Fan Filter Unit (FFU) and where is it used?

    A Fan Filter Unit (FFU) is a self-powered air purification ceiling unit designed to deliver clean air by filtering out airborne particulates. It is widely used in semiconductor manufacturing, pharmaceutical sterile filling lines, hospital operating rooms, and precision laboratories.

    Q: What is the difference between HEPA and ULPA filters in FFU systems?

    HEPA filters achieve an efficiency of ≥ 99.97% for particles ≥ 0.3μm, suitable for standard cleanrooms. ULPA filters achieve an ultra-high efficiency of ≥ 99.999% for smaller particles (0.1–0.2μm), commonly specified for advanced semiconductor fabrication and high-containment biosafety facilities.

    Q: Why should I choose an EC motor over AC or standard DC motors?

    EC (Electronically Commutated) motors combine the advantages of AC and DC motors. They plug directly into AC power, provide high energy efficiency, lower heat dissipation, reduced noise, and support intelligent group control systems (such as RS485 network control).

    Q: What is the difference between Gel Seal and Mechanical Clamping?

    Gel Seal utilizes a jelly-like sealant channel mating with a knife-edge frame to guarantee zero bypass leakage, ideal for high-standard cleanrooms. Mechanical Clamping uses bolts/springs with rubber or polyurethane gaskets, offering a simpler, cost-effective installation method.

    Q: When should the HEPA/ULPA filter be replaced?

    The filter media must be replaced when dust accumulation causes airflow resistance to exceed acceptable operational limits, when airflow drops below design specifications, or if there is a risk of captured particulate re-entrainment into the clean space.

    Q: Are custom FFU dimensions and specifications supported?

    Yes, custom casing dimensions, materials (SUS/galvanized aluminum steel), motor configurations, and filter efficiencies can be manufactured to fit specific ceiling grid sizes and cleanroom engineering requirements.