Leave Your Message

H14 HEPA Filter Unit - High Efficiency Air Filtration System from China Suppliers and Factory

Introducing our high-quality components manufactured in China: the Spray of Cold Rolled Steel Plate for the Box and Flow Equalization Plate, and the robust Galvanized Steel Sheet used for the Press Block. Our Protective Net options include Aluminum Plate, Spray of Cold Rolled Steel Plate, and Stainless Steel, ensuring durability and reliability.

Enhance your system with our Cold Rolled Plate Spray Regulating Valve, designed for efficient control. We also provide top-grade High Efficiency Filters made from advanced filter samples, achieving an impressive efficiency of 99.99% @ 0.3um and 99.995% @ 0.3um. Our filters meet the EN1822 standard, classified as H13/H14, assuring optimal performance in critical applications.

The operating conditions for our products are well-suited for environments with temperatures ≤ 70℃ and humidity levels ≤ 100% RH, making them ideal for various industrial settings.

As a leading supplier and factory in China, we are committed to delivering quality and performance in every product we manufacture.

    Application Area

    Electronics Industry

    Semiconductor chip fabrication rooms, LCD panel production lines, precision PCB assembly rooms.

    Pharmaceutical & Bioengineering

    Sterile preparation areas, vaccine production lines, Biosafety Laboratories (BSL-2/3), sterile filling lines.

    Healthcare

    Hospital operating rooms, sterile wards, ICUs, bone marrow transplant wards.

    Food & Beverage

    Aseptic packaging areas, probiotic production zones, dairy product fermentation rooms.

    Scientific Research

    Animal laboratories, microbiology labs, precision instrument rooms.

    HEPA Unit Structure

    1. Casing: Usually made of cold-rolled steel plate with powder coating or stainless steel, used to house the filter and the plenum box.
    2. Plenum Box: An empty chamber inside the casing, located above the filter. Its functions are:
    • Pressure Equalization: Converts velocity pressure from the duct into static pressure here, ensuring airflow passes uniformly through the entire surface of the high-efficiency filter media, preventing uneven airflow distribution.
    • Velocity Reduction: Stabilizes airflow and reduces turbulence.
    3. High-Efficiency Particulate Air (HEPA) Filter: This is the core component, typically a HEPA filter.
    4. Diffuser Panel: Installed at the air outlet, usually made of aluminum or plastic. It has regularly arranged holes or slots. Its functions are:
    • Further Airflow Equalization: Ensures clean air is delivered as vertical laminar flow or uniform turbulent flow.
    • Filter Protection: Prevents objects from directly touching the expensive HEPA filter core.
    5. Damping Layer: Some designs include a perforated plate or damping mesh inside the plenum box to assist with airflow distribution.

    The Efficiency of HEPA Filter

    HEPA Standard

    Filtering efficiency ≥ 99.97% for particles ≥ 0.3μm.

    ULPA Ultra-High Standard

    A higher-grade filter, efficiency ≥ 99.999% (for 0.1-0.2μm particles). Used in ultra-high standard fields like semiconductors and biosafety laboratories.

    Service Life of Filters

    As dust accumulates on the filter media, the resistance increases. When the resistance reaches an unreasonable level, the filter must be discarded. Sometimes, excessive resistance can cause previously captured dust to become dislodged and re-enter the airflow; when this risk arises, the filter should also be replaced. The resistance of a filter increases with higher airflow rates. By increasing the surface area of the filter media, the relative velocity of air passing through the filter can be reduced, thereby decreasing the resistance.

    Product Structure Description

    Product Structure description

    Wind Speed Relationship Diagram

    Wind speed relationship diagram

    Technical Parameters

    Technical Parameters 2

    Remarks: (1) Initial resistance tolerance of ± 10%  |  (2) Support customer size

    Frequently Asked Questions (FAQ)

    What is the difference between HEPA and ULPA filters?
    HEPA filters achieve a filtration efficiency of ≥ 99.97% for particles ≥ 0.3μm, making them ideal for standard cleanroom and medical applications. ULPA filters provide ultra-high efficiency of ≥ 99.999% for smaller particles (0.1–0.2μm), suitable for advanced semiconductor fabrication and high-containment biosafety labs.
    What is the purpose of the plenum box in a HEPA unit?
    The plenum box equalizes air pressure by converting velocity pressure into static pressure, ensuring airflow is distributed uniformly across the entire filter surface. It also stabilizes the air stream and minimizes turbulence.
    When should a HEPA filter be replaced?
    A HEPA filter must be replaced when dust accumulation causes airflow resistance to exceed acceptable operational limits, or when high resistance creates a risk of dislodging captured particles back into the clean environment.
    Why is a diffuser panel installed at the air outlet?
    The diffuser panel delivers clean air uniformly as vertical laminar flow or controlled turbulent flow while physically protecting the delicate HEPA filter media from accidental contact or damage.
    Are custom sizes available for these HEPA units?
    Yes, custom dimensions, materials (cold-rolled steel with powder coating or stainless steel), and technical specifications can be tailored to meet unique cleanroom duct and ceiling grid requirements.