Leave Your Message

H14 HEPA Filter Unit - High Efficiency Air Purifier from China Suppliers and Factory, 99.99% Filtration at 0.3um

,

Introducing our advanced cold rolled steel plate products, including the Box and Flow Equalization Plate, expertly crafted by our factory in China. Each component undergoes a precise spray coating process to enhance durability and performance.

,

The Press Block is constructed from high-quality galvanized steel sheet, providing robust support for various applications. Our Protective Net options are available in aluminum plate, cold rolled steel plate, or stainless steel, ensuring superior protection and longevity.

,

Equipped with a Regulating Valve, also made from cold rolled plate spray, our products are designed for optimal control and efficiency. The Heat Insulation Cotton is made from PE, offering exceptional insulation properties.

,

For air filtration, our High Efficiency Filter samples achieve an impressive efficiency rating of 99.99%@0.3um and 99.995%@0.3um, meeting the stringent standards of EN1822, Class H13/H14.

,

Our products are suitable for various operating conditions, with a temperature rating of ≤70℃ and humidity levels up to 100%RH. As a leading supplier in the industry, we take pride in delivering high-quality components that meet the needs of our customers.

,

    Application Area
    Electronics Industry

    Semiconductor chip fabrication rooms, LCD panel production lines, precision PCB assembly rooms.

    Pharmaceutical & Bioengineering

    Sterile preparation areas, vaccine production lines, Bio Safety Laboratories (BSL-2/3), sterile filling lines.

    Healthcare

    Hospital operating rooms, sterile wards, ICUs, bone marrow transplant wards.

    Food & Beverage

    Aseptic packaging areas, probiotic production zones, dairy product fermentation rooms.

    Scientific Research

    Animal laboratories, microbiology labs, precision instrument rooms.

    HEPA Unit Structure
    • 1 Casing: Usually made of cold-rolled steel plate with powder coating or stainless steel, used to house the filter and the plenum box.
    • 2 Plenum Box: An empty chamber inside the casing, located above the filter. Its functions are: Pressure Equalization — converts velocity pressure from the duct into static pressure, ensuring airflow passes uniformly through the entire surface of the high-efficiency filter media, preventing uneven airflow distribution. Velocity Reduction — stabilizes airflow and reduces turbulence.
    • 3 High-Efficiency Particulate Air (HEPA) Filter: This is the core component, typically a HEPA filter.
    • 4 Diffuser Panel: Installed at the air outlet, usually made of aluminum or plastic, with regularly arranged holes or slots. Functions include: Further Airflow Equalization — ensures clean air is delivered as vertical laminar flow or uniform turbulent flow. Filter Protection — prevents objects from directly touching the expensive HEPA filter core.
    • 5 Damping Layer: Some designs include a perforated plate or damping mesh inside the plenum box to assist with airflow distribution.
    The Efficiency of HEPA Filter
    HEPA
    ≥ 99.97%

    Filtering efficiency for particles ≥ 0.3μm. The standard high-efficiency filter widely used across cleanroom environments.

    ULPA
    ≥ 99.999%

    A higher-grade filter for 0.1–0.2μm particles. Used in ultra-high standard fields like semiconductors and biosafety laboratories.

    HEPA Filter (1)
    HEPA Filter (3)
    HEPA Filter (4)
    HEPA Filter (5)
    Service Life of Filters

    As dust accumulates on the filter media, the resistance increases. When the resistance reaches an unreasonable level, the filter must be discarded. Sometimes, excessive resistance can cause previously captured dust to become dislodged and re-enter the airflow; when this risk arises, the filter should also be replaced.

    The resistance of a filter increases with higher airflow rates. By increasing the surface area of the filter media, the relative velocity of air passing through the filter can be reduced, thereby decreasing the resistance.

    Product Structure Description
    Product Structure description
    Wind Speed Relationship Diagram
    Wind speed relationship diagram
    Technical Parameters
    Technical Parameters 2

    Remarks: (1) Initial resistance tolerance of ±10%    (2) Support customer size

    Frequently Asked Questions
    Q What is a HEPA filter unit and how does it work?
    A HEPA (High-Efficiency Particulate Air) filter unit is a cleanroom air delivery device consisting of a casing, plenum box, HEPA filter, and diffuser panel. It works by drawing air through the plenum box to equalize pressure, then forcing it through the HEPA filter media to capture particles ≥ 0.3μm with at least 99.97% efficiency, and finally distributing clean air evenly through the diffuser panel as laminar flow.
    Q What is the difference between HEPA and ULPA filters?
    HEPA filters achieve a minimum filtration efficiency of 99.97% for particles ≥ 0.3μm and are suitable for most cleanroom applications including pharmaceuticals, hospitals, and food processing. ULPA (Ultra-Low Penetration Air) filters offer a higher efficiency of ≥ 99.999% for particles as small as 0.1–0.2μm, making them ideal for ultra-critical environments such as semiconductor fabrication and biosafety laboratories.
    Q How long does a HEPA filter unit last, and when should it be replaced?
    The service life of a HEPA filter depends on the operating environment, airflow rate, and the concentration of airborne particles. As dust accumulates, airflow resistance increases. The filter should be replaced when resistance reaches an unacceptable level, or when there is a risk that accumulated dust particles could become dislodged and re-enter the airstream, compromising cleanroom integrity.
    Q What industries require HEPA filter units?
    HEPA filter units are widely used across multiple industries, including: Electronics (semiconductor chip fabrication, LCD panel production, PCB assembly), Pharmaceuticals & Bioengineering (sterile preparation, vaccine production, BSL-2/3 labs), Healthcare (operating rooms, ICUs, sterile wards), Food & Beverage (aseptic packaging, probiotic and dairy production), and Scientific Research (animal labs, microbiology labs, precision instrument rooms).
    Q What is the purpose of the plenum box in a HEPA unit?
    The plenum box is an empty chamber located above the HEPA filter inside the unit casing. It serves two key functions: first, it equalizes pressure by converting velocity pressure from the duct into static pressure, ensuring that airflow is distributed uniformly across the entire surface of the filter media; second, it reduces air velocity and stabilizes airflow to minimize turbulence before the air passes through the filter.
    Q Can HEPA filter units be customized to specific sizes?
    Yes, HEPA filter units can be manufactured to support customer-specified dimensions. The technical parameters table provides standard size options, and custom sizing is available to accommodate different cleanroom ceiling grid layouts or airflow requirements. The initial resistance tolerance is ±10% across all standard and custom configurations.