Leave Your Message

HEPA Unit with H14 HEPA Filter - High Efficiency Air Purifier from China Suppliers and Factory

,

Introducing our premium quality air filtration system, designed and manufactured in China by trusted suppliers and experienced factory specialists. Each component is crafted with precision, ensuring durability and efficiency.

,

【Box】Constructed from cold rolled steel plate with a robust spray finish for enhanced protection.

,

【Flow Equalization Plate】Made from high-quality cold rolled steel plate, this component ensures optimal airflow distribution.

,

【Press Block】Manufactured using galvanized steel sheet for exceptional strength and corrosion resistance.

,

【Protective Net】Available in aluminum plate, cold rolled steel plate, or stainless steel, providing versatile options for various applications.

,

【Regulating Valve】Made from cold rolled plate with a protective spray finish for long-lasting performance.

,

【Heat Insulation Cotton】Utilizing PE material to effectively insulate and maintain temperature stability.

,

【High Efficiency Filter】Featuring advanced filtration technology, our high efficiency filter samples achieve efficiencies of 99.99%@0.3um and 99.995%@0.3um, meeting stringent standards.

,

Standards: EN1822, Class H13/H14, ensuring top-tier performance in air quality management.

,

Operating Conditions: Suitable for temperatures up to 70℃ and humidity levels of up to 100% RH, making it ideal for various environmental circumstances.

,

    Application Area

    Electronics Industry
    Semiconductor chip fabrication rooms, LCD panel production lines, precision PCB assembly rooms.
    Pharmaceutical & Bioengineering
    Sterile preparation areas, vaccine production lines, Bio safety Laboratories (BSL-2/3), sterile filling lines.
    Healthcare
    Hospital operating rooms, sterile wards, ICUs, bone marrow transplant wards.
    Food & Beverage
    Aseptic packaging areas, pro biotic production zones, dairy product fermentation rooms.
    Scientific Research
    Animal laboratories, microbiology labs, precision instrument rooms.

    HEPA Unit Structure

    • Casing:
      Usually made of cold-rolled steel plate with powder coating or stainless steel, used to house the filter and the plenum box.
    • Plenum Box:
      An empty chamber inside the casing, located above the filter. Its functions are:
      Pressure Equalization: Converts velocity pressure from the duct into static pressure here, ensuring airflow passes uniformly through the entire surface of the high-efficiency filter media, preventing uneven airflow distribution.
      Velocity Reduction: Stabilizes airflow and reduces turbulence.
    • High-Efficiency Particulate Air (HEPA) Filter:
      This is the core component, typically a HEPA filter.
    • Diffuser Panel:
      Installed at the air outlet, usually made of aluminum or plastic. It has regularly arranged holes or slots. Its functions are:
      Further Airflow Equalization: Ensures clean air is delivered as vertical laminar flow or uniform turbulent flow.
      Filter Protection: Prevents objects from directly touching the expensive HEPA filter core.
    • Damping Layer:
      Some designs include a perforated plate or damping mesh inside the plenum box to assist with airflow distribution.

    The efficiency of HEPA Filter

    HEPA: Filtering efficiency ≥ 99.97% for particles ≥ 0.3μm.

    ULPA: A higher-grade filter, efficiency ≥ 99.999% (for 0.1-0.2μm particles). Used in ultra-high standard fields like semiconductors and bio safety laboratories.

    HEPA Filter (1)HEPA Filter (3)
    HEPA Filter (4)HEPA Filter (5)

    Service Life of Filters

    As dust accumulates on the filter media, the resistance increases. When the resistance reaches an unreasonable level, the filter must be discarded. Sometimes, excessive resistance can cause previously captured dust to become dislodged and re-enter the airflow; when this risk arises, the filter should also be replaced. The resistance of a filter increases with higher airflow rates. By increasing the surface area of the filter media, the relative velocity of air passing through the filter can be reduced, thereby decreasing the resistance.

    Product Structure description

    Product Structure description

    Wind speed relationship diagram

    Wind speed relationship diagram

    Technical Parameters

    Technical Parameters 2
    Remarks: (1) Initial resistance tolerance of ± 10% (2) Support customer size

    Frequently Asked Questions

    Q1: Which industries benefit most from HEPA filter units?
    HEPA filter units are widely used in cleanroom environments across the Electronics Industry (semiconductors, LCD panels, PCBs), Pharmaceutical & Bioengineering (sterile preparation, vaccine lines, BSL labs), Healthcare (operating rooms, ICUs), Food & Beverage (aseptic packaging), and Scientific Research laboratories.
    Q2: What is the purpose of a Plenum Box in a HEPA unit structure?
    The plenum box functions to achieve pressure equalization by converting velocity pressure into static pressure, ensuring uniform airflow across the filter media. It also stabilizes airflow and reduces turbulence.
    Q3: What is the efficiency difference between HEPA and ULPA filters?
    HEPA filters provide a filtration efficiency of ≥ 99.97% for particles ≥ 0.3μm. ULPA filters offer a higher efficiency of ≥ 99.999% for smaller particles ranging from 0.1 to 0.2μm, making them ideal for ultra-high standard cleanrooms.
    Q4: When should a HEPA filter be replaced?
    Filters must be replaced when dust accumulation increases resistance to an unreasonable level, or when excessive resistance threatens to cause captured dust to dislodge and re-enter the airflow.
    Q5: How can airflow resistance be reduced in filter designs?
    By increasing the surface area of the filter media, the relative velocity of air passing through the filter can be reduced, which subsequently decreases the overall operating resistance.
    Q6: Are custom sizes supported for HEPA filter installations?
    Yes, according to the technical parameters, custom sizes are supported to fit specific client requirements and system configurations.